2-28 SPARC Enterprise M8000/M9000 Servers Service Manual • June 2010
2.6.2 Monitoring Output
To understand error conditions, collect monitoring output information, by using the
commands shown below.
TABLE 2-9 lists the commands for checking the monitoring output.
TABLE 2-8 Predictive Self Healing Message
Output displayed Description
Nov 1 16:30:20 dt88-292 EVENT-TIME: Tue Nov 1 16:30:20 PST 2005 EVENT-TIME: the time stamp of
the diagnosis.
Nov 1 16:30:20 dt88-292 PLATFORM: SUNW,A70, CSN: -, HOSTNAME:
dt88-292
PLATFORM: A description of the
server encountering the problem.
Nov 1 16:30:20 dt88-292 SOURCE: eft, REV: 1.13 SOURCE: Information on the
Diagnosis Engine used to
determine the fault.
Nov 1 16:30:20 dt88-292 EVENT-ID:
afc7e660-d609-4b2f-86b8-ae7c6b8d50c4
EVENT-ID: The Universally
Unique event ID for this fault.
Nov 1 16:30:20 dt88-292 DESC:
Nov 1 16:30:20 dt88-292 A problem was detected in the PCI-Express
subsystem
DESC: A basic description of the
failure.
Nov 1 16:30:20 dt88-292 Refer to http://sun.com/msg/SUN4-8000-0Y for
more information.
WEBSITE: Where to find specific
information and actions for this
fault.
Nov 1 16:30:20 dt88-292 AUTO-RESPONSE: One or more device instances
may be disabled
AUTO-RESPONSE: What, if
anything, the system did to
alleviate any follow-on issues
Nov 1 16:30:20 dt88-292 IMPACT: Loss of services provided by the device
instances associated with this fault
IMPACT: A description of what
that response might have done.
Nov 1 16:30:20 dt88-292 REC-ACTION: Schedule a repair procedure to
replace the affected device. Use Nov 1 16:30:20 dt88-292 fmdump -v -u
EVENT_ID to identify the device or contact Sun for support.
REC-ACTION: A short description
of what the system administrator
should do.