Fujitsu M8000 Server User Manual


 
Appendix E XSCF Unit Replacement When XCP 1040 or 1041 Is in the Server E-3
19. Confirm switching over between XSCFs works properly.
a. When the READY LED on XSCFU_B#1 remains lit, log in to XSCFU#0 using
a serial connection or LAN connection.
b. Confirm switching over between XSCFs using the following commands:
Confirm XSCFU#1 is now the standby, and that XSCFU#0 has become the active.
Confirm no new errors have been recorded since the check in Step 14.
Confirm a message "XSCFU entered active state from standby state".
Confirm a message “No failures found in System Initialization”.
20. Power on all domains.
21. Log in to XSCFU#0 and confirm all domains start up properly.
22. Check that there are no new errors.
In case an abnormality is encountered, take appropriate maintenance action and
contact service engineer.
If no abnormality is found, proceed to Step 23.
XSCF> switchscf -t Standby
The XSCF unit switch between the Active and Standby states.
Continue? [y|n] :y
XSCF> showhardconf
XSCF> showlogs error
XSCF> showlogs event
XSCF> showstatus
XSCF> poweron -a
XSCF> showlogs power
XSCF> showlogs error