11-6 SPARC Enterprise M8000/M9000 Servers Service Manual June 2010
3. Use the maintenance menu to select the XSCFU to be replaced. (The
maintenance menu is used up to Step 10.)
The fieldeng permission is required for executing this command.
a. From the console that is connected to the Active XSCF, log in to the XSCF,
and execute the replacefru command.
As shown in
FIGURE 11-4, the initial page of the maintenance menu is displayed.
FIGURE 11-4 Initial Page of the Maintenance Menu
Note – DDC_A is displayed only for the M8000
b. From the replacement parts list on the maintenance menu, select 4, "XSCFU."
c. From here, perform the operation according to the guidance displayed in the
maintenance menu.
Check the states of LEDs (POWER LED: off; CHECK LED: blinking) on the
XSCFU to be replaced, and begin the actual replacement work when a message
instructing the user to replace the target XSCFU is displayed. Leave the
maintenance menu as is until Step 6.
4. Connect the clip of the antistatic wrist strap and of the antistatic mat to the
server grounding port. See Section 1.4, “Antistatic Precautions” on page 1-6.
---------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. CMU/IOU(CPU Memory Board Unit/IO Unit)
2. FAN(Fan Unit)
3. PSU(Power Supply Unit)
4. XSCFU(Extended System Control Facility Unit)
5. DDC_A(DDC for BP_A)
---------------------------------------------------
Select [1-5|c:cancel] :