Fujitsu PRN607-S Printer User Manual


 
MAN607-S
28-03-2003 Page 4-25 of 53
4.9.24 Request Temperature
[Name] Request Temperature
[Format] ASCII SUB
Hex 1A
Decimal 26
[Description] When the printer controller receives this byte the digital
value of the head temperature will be transmitted. This
command can be treated even if buffer is full
4.9.25 Sub command set
[Name] Sub command set
[Format] ASCII ESC n
Hex 1B n
Decimal 27 n
[Range] n: [-128;127]
[Description] The n is the commands in the sub-set.
4.9.26 Upgrade command
[Name] Upgrade command
[Format] ASCII ESC Z
Hex 1B 5A
Decimal 27 90
[Description] Only used by the I/F-COM A/S upgrade programs.
4.9.27 Set auxiliary output
[Name] Set auxiliary output
[Format] ASCII ESC p n
Hex 1B 70 n
Decimal 27 112 n
[Description] When this command is received then the
auxiliary output can be set.
If n = 0, then the output will be set to off
If n > 1 and < 254 then the output will be
turned on in n/4.096msec, and then turned
off again.
If n = 255, then the output will be turned on.