Fujitsu PRN607-S Printer User Manual


 
MAN607-S
28-03-2003 Page 2-8 of 53
(a) To connect or remove the connector, always turn off the power in
advance. If the connector is connected or removed while the power
to the printer is on, errors may occur.
(b) The connector of each cable must be correctly locked and connected.
The connector at the head side has no lock feature. Check that the
connector at the head side is completely inserted.
(c) To install the interface, carefully check each cable so that excessive
force is not applied to each cable. Especially, carefully check the
head connection cable because it affects the head pressure force. If
the print head connector is not completely connected, overheating or
burning may occur in the print head.
(d) Be sure to add grounding cable from printer body to interface ground.
Make sure that ground is present at any mechanical settings, like
head up and paper out.
2.4 Power supply
Single power supplies for the PRN607-S controller board. Voltage range is
18-26VDC. 5A minimum @ 24V. Make sure that voltages never exceed
26VDC.
(a) The power supply unit that satisfies the specified specifications must
be used. If a power supply unit that does not satisfy the specified
specifications is used, normal operation is not assured and errors
may occur.
(b) To turn on or off the power, a protective circuit must be mounted on
the control board in advance. For safety, the following voltage
change conditions must be satisfied:
2.5 Settings
Following below description can change default settings. Baud rate is
default 115.200, however standard PC´s today cannot handle this Baud
rate. Windows OS does not support speed higher than 115.200 Baud, even
when setup menus can be set to higher speed. In order to obtain higher