Fujitsu RX200 S5 Laptop User Manual


 
RX200 S5 Options Guide 23
5 Processors
V CAUTION!
Follow the safety instructions in the chapter “Safety instructions” on
page 13.
V CAUTION!
Processors are modules which can react extremely sensitively to electro-
static discharges and which must therefore always be handled with care.
After a processor has been removed from its protective sleeve or from its
socket, place it with its smooth side down on a non-conducting, antistatic
surface.
Never push a processor over a surface.
5.1 Installing a second processor
The system board can be upgraded with a second processor.
V CAUTION!
Only processors of the same type may be used on the system board. The
second processor must have the same clock frequency as the first. For
dual operation, use a suitable multiprocessor operating system.
Ê Open the server as described in chapter “Preparation” on page 19.
Ê Lift the air cowl upwards to remove it as described in section “Removing the
air cowl” on page 22.