Processors Replacing the heat sin
k
5.3 Replacing the heat sink
Ê Open the server as described in chapter “Preparation” on page 19.
Ê Lift the air cowl upwards to remove it as described in section “Removing the
air cowl” on page 22.
Ê Remove the four screws of the heat sink in a crossover pattern (see figure 9
on page 26).
Ê Loosen the heat sink carefully by turning it back and forth. Then lift it up and
off.
Ê Clean the upper side of the processor using a lint-free cloth.
I New heat sinks come with thermal paste already applied. When reusing
used heat sinks, you need to apply thermal paste.
Ê Place the heat sink on the processor (see figure 8 on page 25).
Ê Fasten the heat sink by tightening the four screws in a crossover pattern (see
figure 8 on page 25).
Ê Fit the air cowl as described in chapter “Completion” on page 61.
Ê Close the server, connect all power plugs to the power outlets, and switch on
the server as described in chapter “Completion” on page 61.