Environmental specifications
www.gateway.com
Environmental specifications
The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
Variable Requirements
Temperature Maximum rate of change: 18°F (10°C) per hour
Nonoperating: -55° to 150°F (-48.3° to 65.5°C)
Operating: 41° to 95°F (5° to 35°C); derated 0.9°F (0.5°C) for every
1,000 feet (305 meters)
Altitude
10,000 feet (3,048 meters) maximum
Humidity
Operating wet bulb: Not to exceed 91.4°F (33 °C) (with diskette drive
or hard drive)
Nonoperating: 95% relative (noncondensing) at 86° F (30° C)
Shock
Operating: 2.0 g, 11 msec, ½ sine
Packaged: Operational after 30-inch free fall (cosmetic damage might
occur)
AC input power 100-240 V, 8.0 A, 50/60 Hz