HP (Hewlett-Packard) 441877-00B Network Card User Manual


 
Diagnostics 157
Prerequisites
The diagnostic utility runs under MS-DOS® v6.22 or later. It will not run from a DOS window in IBM
OS/2® or any Microsoft Windows products. This utility is designed to test hardware operation and
confirm the adapter's ability to communicate with another adapter in the same network, which primarily
confirms cabling status.
This diagostic utility is not a throughput measurement tool. The utility can test the adapter whether or not
there is a responder on the network; however, to conduct a thorough test you should set up a second
system on the network as a responder prior to starting a test.
These diagnostics use pmode/w DOS Extender V1.33.
Input file list: The following files should be found in the same location as the q57diag.exe file.
o 5701.bin
o 5703.bin
o config.sys
o cpu05.bin
o cpu.bin
o cpu14a.bin
o cpu14b.bin
o cpudg05.bin
o cpudiag.bin
o cpusj.bin
o cpumem.bin
o diagcfg.bin
o flshdg05.bin
o flshdg5x.bin
o flshdiag.bin
o flshd14a.bin
o flshd14b.bin
o flshdgsj.bin
o q57diag.exe
o ump14a.bin
o ump14b.bin
Do not use emm386.exe. Himem.sys and emm386.exe are both memory managers. If they are both
loaded, the diags aborts and the following error may occur:
Exception: OE
Error Code: 00000000
About the Q57DIAG.exe diagnostic tests
The tests are divided into four groups: Register tests, Memory tests, Miscellaneous tests, and Data tests.
They are identified as group A, B, C, and D.
Group A: Register tests
A1. Indirect register test