HP (Hewlett-Packard) 441877-00B Network Card User Manual


 
Diagnostics 165
o
dflt = 1
-rstpl <x> <y>
o <x> = post GRC rst poll interval, dly in ms; dflt = 10
o <y> = post GRC rst poll count; dflt = 0 (disable)
-rstpld
Above post reset polling counts display enable.
-addref (x)
Added a ref card info of dev <x> to refinfo.txt
-blink <x>
Blinks the LED on the selected device
-rf <x>
Selects a reference device for test D3
-sil
Used before the -firm and -firmall options to hide warnings
-exe
Executes diags commands without a device present
-updateasfcfg
Used with the -firmall option to include updating ASF CFG block
-updateumpcfg
Used with the -firmall option to include updating UMP CFG block
-pump <file>
Option to program UMP firmware
-updatesecfg
Used with the -firmall option to include updating SE CFG block
-mfct <file>
Programs a new SSID and SVID based on <file>
-fail2
On failure offsets failed message printout
-logfl
Log file buffer flush per line
-nosz
Do not write the NVRAM with the TPM/NVRAM size
Error codes and messages
1. Got 0x%08x @ 0x%08x. Expected 0x%08x
2. Cannot run test while chip is running
3. Invalid adapter device
4. Read only bit %s got changed after writing zero at offset 0x%X