HP (Hewlett-Packard) RP3410 Server User Manual


 
Table 3-12 Front Control Panel LED Definitions (continued)
DescriptionColorFlash RateStateLED/Button
Warning: System needs attention. Redundancy
lost, component failure pending. (Additional
information can be found in the System Log)
YellowFlashing at 1
Hz
AttentionSystem
Hard fault, system haltedRedFlashing at 2
Hz
FaultSystem
System offN/AOffOffSystem
Power normalGreenSteadyOnPower
Housekeeping voltage presentYellowFlashing at 1
Hz
OnPower
Power offOffOffOffPower
Disk activityGreenFlashing at
rate of disk
activity
Disk LED
Thermal OKGreenSteadyOKThermal LED
Thermal warningYellowFlashing at 1
Hz
WarningThermal LED
System locator LED can be remotely or locally
activated or deactivated
BlueFlashing at 1
Hz
Locator
LED/button
Information to Collect Before You Contact Support
Before you contact HP support:
1. Check information on troubleshooting and attempt to solve the problem.
Note failure symptoms and error indications (LEDs and messages) by checking the SEL.
Try to determine precisely what did or did not happen.
2. Collect the following information:
The model number of the server (for example, HP 9000 rp3440)
The product number of the server. This is found on the identification label, which is
found at the front of the unit (typically A9956A, A9951A, and so on).
The serial number of the server. This is found on the identification label.
3. Become familiar with the server configuration:
Are you using the LAN, RS232, or web interface to monitor the server?
How many processors, DIMMs, and PCI cards have been installed?
What versions of processor, memory, and PCI cards are used and where are they
installed?
What accessories are installed?
4. Determine the following:
Which firmware versions are in use?
When did the problem start?
Have recent changes been made to the system?
Which operating system and version is in use?
108 Installing the System