HP (Hewlett-Packard) RP3410 Server User Manual


 
3. Issue the shutdown command with the appropriate command-line options.
The command-line options you specify dictate the way in which HP-UX shuts down, and
whether the server is rebooted.
Use the following list to choose an HP-UX shutdown option for the server:
To shut down HP-UX and halt (power off) the server, issue the shutdown -h command.
To reboot a halted server you must power on the server using the PC command at the
iLO MP Command menu.
To shut down HP-UX and reboot the server, issue the shutdown -r command.
Verifying the Server Configuration Using Boot Console Handler
To go the Information Menu, enter in from the BCH Main Menu. Use the corresponding command
from the menu to verify the enter and quantity of processors, memory, and I/O cards:
1. To enter the POSSE shell, enter CO from the iLO MP Main Menu. To list all the categories
available in the shell, enter help .
pr (Processors)
me (Memory)
io (Check the PCI device information to determine if the values match the devices
installed in the server)
2. Verify the parameters.
3. To return to the BCH Main Menu, use the ma command .
Verifying the Server Configuration Using Boot Console Handler 111