C Physical and Environmental Specifications
Table C-1 provides temperature and airflow information for minimum, typical, and maximum
configurations for the HP 9000 rp3410 and rp3440 servers. It also lists the server and rack weights
and dimensions.
Table C-1 Physical and Environmental Specifications
Overall Server (W x D
x H)
WeightCondition
Airflow, at
Maximum
Ambient degrees
C
1
Airflow, NominalTypical
Heat
Release
Pede-stalRackPede-
stal
RackServer
Alone
100-250
VAC
W: 11.6 in
(29.5 cm)
D: 26.6 in
(67.5 cm)
H: 19.5 in
(49.4 cm)
W: 19.0 in
(48.3 cm)
D: 26.8 in
(67.9 cm)
H: 3.4 in
(8.6 cm)
56.3 lbs
(25.5
kg)
49.0 lbs
(22.2 kg)
38.6 lbs
(17.5 kg)
115.94
m3/hr
68.2
CFM
98.3
m3/hr
57.8
CFM
341 WattsMin.
Config.
536 WattsMax.
Config.
426 WattsTypical
Config.
One dual-core CPU, one power supply, 2 GB DIMM,
zero DVD, three HDDs.
Min./
Config.
Airflow cooling scheme (front to rear)ASHRAE
Class 1
Two dual-core CPUs, one power supply, 32 GB
DIMM, one DVD, three HDDs, one graphics card,
one SCSI card.
Max.
Config.
One dual-core CPU, one power supply, 6 GB DIMM,
one DVD, three HDDs, one graphics card, one SCSI
card.
Typical
Config.
1 Derate maximum dry bulb temperature 1 degree per 300 meters above 900 meters.