Hitachi MK-96RD626-07 Computer Drive User Manual


 
Performing Universal Volume Manager Operations 5-23
Hitachi Universal Storage Platform V/VM Universal Volume Manager User’s Guide
Figure 5-11 Pop-up Menu of Configure Cross-subsystem Paths Dialog
Box
Changing the Configured Cross-subsystem Path Priority
To change the cross-subsystem path priority, use the Raise Priority
command and the Lower Priority command displayed in the Configure Cross-
subsystem Paths dialog box.
The following is an example of procedure to make the cross-subsystem path to
the currently used path by raising the priority of the cross-subsystem path:
1. Start Storage Navigator, and open the Volume Operation window.
2. Make sure that Storage Navigator is in Modify mode.
3. Click the path group to which the cross-subsystem path belongs in the
Volume Operation tree.
4. Right-click the cross-subsystem path in Cross-subsystem Paths in the
Volume Operation list.
5. Click Configure Cross-subsystem Paths in the pop-up menu.
The Configure Cross-subsystem Paths dialog box is displayed.
6. Right-click the cross-subsystem path that you want to change the priority
of in the Selected Paths in the Configure Cross-subsystem Paths dialog
box.
7. Click Raise Priority in the pop-up menu
The row of the selected path switches with the one row above.