Hitachi MK-96RD626-07 Computer Drive User Manual


 
Connecting External Storage Systems A-5
Hitachi Universal Storage Platform V/VM Universal Volume Manager User’s Guide
Thunder 9500V Storage System
System Parameters for Connecting Thunder 9500V
The table below explains whether to specify system parameters when making
settings on ports on the Thunder 9500V storage system.
Table A-5 System Parameter Settings (9500V)
Window Names Parameters Parameter Settings
System Startup
Settings
Start Attribute
Single Mode
Specify this parameter when Thunder 9500V
storage system is in the one controller
configuration.
Dual Active Mode
Specify this parameter when Thunder 9500V
storage system is in the two controller
configuration.
Note: Be sure to specify that Data Share
Mode will be used.
Hot Stand-By Mode Do not specify this parameter.
Common 1 Delay Planned Shutdown
You can either specify this parameter or
omit specifying this parameter.
OPTION 1
SCSI Fibre Channel Common
Options
You can either specify this parameter or
omit specifying this parameter.
OPTION 2
SCSI Fibre Channel Common
Options
You can either specify this parameter or
omit specifying this parameter.
Data Striping
Operation if the processor
failure occurs
Specify this parameter to Reset of occurred.
Command Queuing Mode Specify this parameter ON.
Vendor ID
Keep this parameter as HITACHI (default),
and do not change.
Product ID
Keep this parameter as DF600F (default),
and do not change.
ROM Microprogram Version
You can either specify this parameter or
omit specifying this parameter.
RAM Microprogram Version
You can either specify this parameter or
omit specifying this parameter.
Inquiry Setting
WEB Title
You can either specify this parameter or
omit specifying this parameter.
Reset/LIP Mode
Reset/LIP Mode (Signal)
You can either specify this parameter or
omit specifying this parameter.
Port Type
Reset/LIP Mode (Process)
You can either specify this parameter or
omit specifying this parameter.