Intel SE7525GP2 Computer Hardware User Manual


 
Intel® Server Board SE7320SP2 & Intel Server Board SE7525GP2 TPS Platform Management
Revision 2.0
130
Sensor Name
Sensor
#
Sensor
Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value/Offsets
Event Data
PEF
Action
SDR
Record
Type
Tach Fan 3
(Front 3)
19h
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Tach Fan 4
(Front 4)
1Ah
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Tach Fan 5
(Rear 1)
1Bh
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Tach Fan 6
(Rear 2)
1Ch
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Proc1 IERR 1Dh
Processor
07h
Sensor
Specific
6Fh
IERR As Trig Offset 02
Proc2 IERR 1Eh
Processor
07h
Sensor
Specific
6Fh
IERR As Trig Offset 02
Proc1 Thermal
trip
1Fh
Processor
07h
Sensor
Specific
6Fh
Thermal Trip As Trig Offset
Fault
LED
Action
02
Proc2 Thermal
trip
20h
Processor
07h
Sensor
Specific
6Fh
Thermal Trip As Trig Offset
Fault
LED
Action
02
Proc1 Throttle 21h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog Trig Offset
Fault
LED
Action
01
Proc2 Throttle 22h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog Trig Offset
Fault
LED
Action
01
Diagnostic
Interrupt Button
23h
Critical
Interrupt
13h
Sensor
Specific
6Fh
FP NMI
Button
As – Trig Offset
NMI
Pulse
02
Chassis Identify
Button
24h
Button
14h
Generic
03h
Sate
Deasserted
State Assert
As – Trig Offset
ID LED
Action
02
Proc1 Fan 25h
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Proc2 Fan 26h
Fan
04h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Proc1 Core
temp
27h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
Proc2 Core
temp
28h
Temp
01h
Threshold
01h
[u,l][ nr, c,nc] As & De Analog R, T
Fault
LED
Action
01
CPU
Configuration
Error
29h
Processor
07h
Generic
03h
State
Asserted
As & De Discrete R, T
Fault
LED
Action
02