Konica Minolta (FX-3) Fax Machine User Manual


 
7
7.1 Main Error Messages and Their Remedies
7-2 Fax Kit (FX-3)
Appendix Chapter 7
7.1 Main Error Messages and Their Remedies
Message Cause Remedy
LINE PROBLEM The telephone dialing system
or telephone wiring system are
not set correctly.
The telephone cable is not
attached correctly.
Check the telephone dialing
system or telephone wiring
system and use the
appropriate Utility mode
function to make the correct
settings.
Correctly connect the
telephone cable.
(Flashing alternately)
CHECK LINE
COMM.ERROR
(####)
Communication is not possible
because of some problem in
the machine.
Communication is not possible
because of a problem with the
recipient/callers fax machine.
Check the transmission results.
REDIAL ALL FAILED All redial attempts failed because
either the recipients line is busy
or there was no answer.
Check the condition of the
recipients line, and then try
sending the fax again.
MEM.FULL/TX CANCEL While sending a fax, the size of
the data for the scanned image
has exceeded the capacity of the
memory.
Retrieve all received faxes
stored in the memory.
Send the fax by direct
transmission.
MEM.FULL/RX CANCEL While receiving a fax, the size of
the data for the scanned image
has exceeded the capacity of the
memory.
Retrieve all received faxes stored
in the memory.
HANG UP THE PHONE The receiver of the connected
telephone is lifted.
Replace the receiver of the
connected telephone on the
hook.
TEXT
×1.00 1
ä[A]ü #XXX: Fax Err
A fax error occurred while an
operation was being performed in
Copy mode.
Press the [Fax] key to check the
error condition, and take
appropriate measures.
TEXT
×1.00 1
ä[A]ü #XXX: Comm.Err
A fax transmission error occurred
while an operation was being
performed in Copy mode.
Press the [Fax] key to check the
error condition, and take
appropriate measures.
PLEASE WAIT!
ADMINISTERED BY PC
This machine is accessing LSD,
RSD or the Admin. Mode of
PageScope Light.
Log off from PageScope Light
or LSD or quit communications
with RSD.
If no operation is performed for
600 seconds, the main screen
appears.