Attention: For proper cooling and airow, replace the bezel and server cover before you turn on the
server.
To install the bezel, insert the tab at the right end of the bezel into the front of the chassis and pivot the
bezel until it snaps into place.
Attention: For proper cooling and airow, replace the server cover before you turn on the server.
Removing and installing the DIMM air bafe
The DIMM air bafe must be removed to allow access to some of the server components. To remove and
install the DIMM air bafe, complete the following procedures:
Removing the DIMM air bafe
To remove the DIMM air bafe, complete the following steps:
1. Read the safety information in “Important Safety Information” on page 1 and “Guidelines for trained
service technicians” on page 115.
2. Turn off the server and peripheral devices and disconnect all power cords and external cables.
3. Remove the server from the rack and remove the cover (see “Removing and installing the cover” on
page 119).
4. Lift the DIMM air bafe 1 up and out of the server.
Attention: For proper cooling and airow, reinstall the DIMM air bafe before you turn on the server.
Operating the server with the air bafe removed might damage server components.
Installing the DIMM air bafe
To install the DIMM air bafe, complete the following steps:
1. Align the DIMM air bafe 1 as shown above.
2. Lower the DIMM air bafe into position until it clicks into place.
Attention: For proper cooling and airow, the air bafe must be installed before turning on the server.
Operating the server with an air bafe removed might damage server components.
3. Go to “Completing the FRU replacement” on page 172.