• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which
components are customer replaceable units (CRU) and which components are eld replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
The Processor CPU nStatus has
Failed with IERR.(n = microprocessor
number)
Error
A processor failed - IERR
condition has occurred.
1. Make sure that the latest levels
of rmware and device drivers
are installed for all adapters
and standard devices, such as
Ethernet, SCSI, and SAS.
Important: Some cluster
solutions require specic code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
2. Run the DSA program for the
hard disk drives and other I/O
devices.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
An Over-Temperature Condition has
been detected on the Processor CPU
nStatus.(n = microprocessor number)
Error An overtemperature
condition has occurred
for microprocessor n.(n =
microprocessor number)
1. Make sure that the fans are
operating, that there are no
obstructions to the airow, that
the air bafe is in place and
correctly installed, and that
the server cover is installed
and completely closed.
2. Make sure that the heat
sink for microprocessor n is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
28 Hardware Maintenance Manual