Lexmark IBM 9077 Network Router User Manual


 
132 IBM 9077 SP Switch Router: Get Connected to the SP Switch
4.4.10 Using grrt to Display the Route Table
Use the grrt -S -p<slot> command to display the current contents of the
FDDI card’s route table, as follows:
# grrt -S -p0
default 1 192.168.4.137 inx 0 RMS
0.0.0.0 255.255.255.255 8 0.0.0.0 inx 0 DROP
10.1.1.0 255.255.255.0 16 0.0.0.0 ga010 FWD
10.1.1.1 255.255.255.255 15 0.0.0.0 ga010 LOCAL
10.1.1.255 255.255.255.255 14 0.0.0.0 ga010 BCAST
10.1.2.1 255.255.255.255 19 0.0.0.0 ga0180 LOCAL
10.10.1.0 255.255.255.0 7 0.0.0.0 bg0 BFWD
10.10.1.13 255.255.255.255 6 0.0.0.0 bg0 BLOCAL
10.10.1.255 255.255.255.255 5 0.0.0.0 bg0 BBCAST
127.0.0.0 255.0.0.0 4 0.0.0.0 inx 0 FWD
127.0.0.1 255.255.255.255 3 127.0.0.1 inx 0 RMS
192.168.4.0 255.255.255.0 10 0.0.0.0 inx 0 RMS
192.168.13.0 255.255.255.0 17 10.1.1.2 ga010 FWD
192.168.14.0 255.255.255.0 13 0.0.0.0 gt030 FWD
192.168.14.4 255.255.255.255 12 0.0.0.0 gt030 LOCAL
192.168.14.255 255.255.255.255 11 0.0.0.0 gt030 BCAST
224.0.0.0 240.0.0.0 2 0.0.0.0 inx 0 MCAST
224.0.0.0 255.0.0.0 2 0.0.0.0 inx 0 MCAST
224.0.0.0 255.255.255.255 2 0.0.0.0 inx 0 MCAST
255.255.255.255 255.255.255.255 9 0.0.0.0 inx 0 BCAST