5-142 Maxtor Atlas 10K V
5.38.1 Supported Diagnostic Page List
Table 5-193 shows the Supported Diagnostic Page List that can be supplied with a
SEND DIAGNOSTIC command to request that the Supported Diagnostic Page List
be returned after the next RECEIVE DIAGNOSTIC RESULTS command.
Table 5-193 Supported Diagnostic Page List-Data Format
5.38.2 Translate Address Page
Table 5-194 shows the Translate Address Page that can be supplied with a SEND
DIAGNOSTIC command to request that the Translate Address Page be returned after
the next RECEIVE DIAGNOSTIC RESULTS command.
Table 5-194 Translate Address Page-Data Format
SelfTest
If the PF bit is 0 and the SelfTest bit is 1, the drive runs its self-test routine. GOOD status is re-
turned to the initiator if the self-test passes. CHECK CONDITION status is returned along with
any available sense data if the self-test fails.
This field is ignored if the PF bit is 1.
DevOnl Any value in this field is ignored by the drive.
UnitOfl Any value in this field is ignored by the drive.
Parameter List
Length
When the Parameter List Length field is non-zero, the value specifies the length (in bytes) of the
parameter list that is to be transferred from the initiator to the drive during the command's data-
out buffer transfer.
This field is only valid when the PF bit = 1 and must be 0 when the PF bit is 0.
Bit
Byte
765 4 3210
0 Page Code (00h)
1 Reserved
2 - 3 Page Length (00h)
Bit
Byte
76543210
0 Page Code (40h)
1 Reserved
2 - 3 Page Length (0Ah)
4
Reserved
Supplied Format
000b (LBA)
5
Reserved
Translate Format
101b (Physical Sector)
6 - 9 Address to Translate
(LBA Format)
10 - 13 Reserved
Field Description