Maxtor Atlas 10K V 4-9
4.9 ELECTROMAGNETIC CONDITIONS
4.9.1 EMI/RFI Susceptibility
3 Volts/meter 80% modulated from 80 to 1000 MHz.
4.9.2 ESD
Drive must function with no data loss or component damage with air discharges
of 1 to 15 KV, and contact discharges of 2 to 8 KV in both positive and negative
voltages.
4.9.3 Sensitivity to Magnetic Fields
The Maxtor Atlas family of drives meet 3A @ 230V / 50 Hz specification.
4.10 SHOCK AND VIBRATION
The Maxtor Atlas 10K V hard disk drive can withstand levels of shock and
vibration applied to any of its three mutually perpendicular axes, or principal base
axis, as specified in Table 4-8. A functioning drive can be subjected to specified
operating levels of shock and vibration. When a drive has been subjected to
specified non-operating levels of shock and vibration, with power to the drive
off, there will be no change in performance at power on.
When packed in its 1-pack shipping container, the Maxtor Atlas 10K V drive can
withstand a drop from 42 inches onto a concrete surface on any of its surfaces,
six edges, or three corners. The 20-pack shipping container can withstand a drop
from 36 inches onto a concrete surface on any of its surfaces, six edges, or three
corners.
Table 4-8 Shock and Vibration Specifications
Note: 1. At ambient temperature and no unrecoverable errors.
PARAMETER OPERATING NON-OPERATING
Shock linear Half Sine
2 msec
1
Read/Write
63G/30G
1
250 G
1
Shock linear Half Sine
11 msec
1
15 G
1
100 G
1
Shock rotational
(rad/s
2
)
1
, 2 msec
7000 25,000
Vibration Swept
1
Vibration Random
(G
2
/Hz)
1.5G 0-p 5-500 Hz
0.008 10—300 Hz
0.0012 300—500 Hz
2.0G 0-p 5–500 Hz
0.014 10—300 Hz
0.01 300—500 Hz