EN-55
Lamp relay
Using the lamp relay function, you can project images
continuously. The lamp relay function automatically
rests or switches the lamps. The lamp relay is
performed when LAMP SELECT in the INSTALLATION
1 menu is set to DUAL or SINGLE.
Setting the lamp relay interval
When LAMP SELECT is set to DUAL:
Either of the lamps is automatically put to rest.
(See page 31 for menu setting.)
1. Display the INSTALLATION 1 menu.
2.
Select LAMP SELECT by pressing the or button.
1
2
LAMP SELECT
DUAL
3. Press the ENTER button.
4. Select DUAL by pressing the or button.
LAMP SELECT
1
2
LAMP SELECT
DUAL
5. Press the ENTER button.
6.
Select LAMP RELAY by pressing the or button.
LAMP RELAY
1H/24H
7. Select 1H/24H
or
2H/1W
by pressing the or
button.
1H/24H .....Select this setting when the lamp
is operated at a specified time of
the day. During the continuous
projection, LAMP 1 or LAMP 2 is
automatically turned off for 1 hour
in 24 hours. After the interval is set,
the lamps are turned off for 1 hour
alternately at the specified interval.
Illuminating
Off
LAMP 1
LAMP 2
1
2345678 (days)
At the time of power-on or menu setting
2H/1W ......During the continuous projection,
LAMP 1 or LAMP 2 is automatically
turned off for 2 hours in a week.
After the interval is set, the lamps are
turned off for 2 hours alternately at
the specified interval.
Illuminating
Off
LAMP 1
LAMP 2
1
2345678 (days)
At the time of power-on or menu setting
8. Press the ENTER button.
• Whenyouselect1H/24H or 2H/1W , the
box to set the lamp relay interval is displayed.
• Whentheprojectoristurnedoff,thesettingis
cleared and the projector resumes operation
from the time of the power-on or menu setting
shown in the preceding step.
1H/24H
NEXT LAMP RELAY
23H
0
OK
CLEAR
DEL
CANCEL
1234567 8 9
← →
2H/1W
NEXT LAMP RELAY
6D 22H
0
OK
CLEAR
DEL
CANCEL
1234567 8 9
← →
9. Move the key cursor using the direction buttons to
select the number you want to enter and then press
the ENTER button.
• Maximuminterval
1H/24H ..... 23H (23 hours)
2H/1W ...... 6D 22H (6 days and 22 hours)
← key: Shifting the position of enter cursor
to the left for each character.
→ key: Shifting the position of enter cursor
to the right for each character.
DEL key: Deleting the character in the
position of enter cursor for each
character.
CLEAR key: Deleting all the entered characters.
• Youcanenterthevaluebypressingthenumber
buttons (0 to 9) while holding down the NUM
button on the remote control.
• Whenthevalueyouenteredmeetsthefollowing
conditions, an error dialog box is displayed at
the screen center.
∙ The value has been cleared by DEL or CLEAR
and left blank.
∙ The value you entered is out of the setting
range.
1H/24H .... 24H or over
2H/1W ..... 6D 23H or over
∙ The value of each item is out of the setting
range.
D .................. 7 or over (2H/1W only)
H .................. 24 or over
10. When selecting OK, the setting is completed as
the lamp-switching interval stored. However, when
selecting CANCEL, the setting is completed without
storing.
• ThedisplayreturnstheLAMPRELAYmenuafter
selecting OK or CANCEL.
• ThesettingyoumadeisappliedtoNEXTLAMP
RELAY in the INFORMATION menu.
Important:
• Whenyouusetheprojectorcontinuously,thelamp
relay may not be performed on time due to errors of
the clock function.