EN-56
• Immediatelyafterthepower-on,duringthelamp
selection, or during the lamp relay operation, you
cannot change the setting of LAMP SELECT and
LAMP RELAY.
• Inthecaseofcontinuousprojection,thelampsmay
deteriorate earlier unless they are turned off for 1
hour per week.
• Whenusingthisprojectorcontinuouslyforalong
time of period, enable LAMP RELAY.
• Thebrightnessandcolortintvaryatthetimeof
lamp switching.
When LAMP SELECT is set to SINGLE:
The lamps are automatically switched and used alternately.
(See page 31 for menu setting.)
1. Display the INSTALLATION 1 menu.
2.
Select LAMP SELECT by pressing the or button.
1
2
LAMP SELECT
DUAL
3. Press the ENTER button.
4. Select SINGLE by pressing the or button.
LAMP SELECT
1
2
LAMP SELECT
SINGLE
5. Press the ENTER button.
6.
Select LAMP RELAY by pressing the or button.
LAMP RELAY
24H
7. Select 24H
or 1 WEEK
by pressing the or
button.
24H ......... The lamps are switched to each other
every day.
Off
Illuminating
LAMP 1
LAMP 2
1
2345678 (days)
At the time of power-on or menu setting
1 WEEK .. The lamps are switched to each other
every week.
LAMP 1
Illuminating
LAMP 2
1
2345678 (days)
Off
At the time of power-on or menu setting
8. Press the ENTER button.
• Whenyouselect24H or 1 WEEK , the box
to set the lamp relay interval is displayed.
24H
NEXT LAMP RELAY
24H
0
OK
CLEAR
DEL
CANCEL
1234567 8 9
← →
Lamp relay (continued)
1 WEEK
NEXT LAMP RELAY
7D 00H
0
OK
CLEAR
DEL
CANCEL
1234567 8 9
← →
9. Move the key cursor using the direction buttons to
select the number you want to enter and then press
the ENTER button.
• Maximuminterval
24H ........... 24H (24 hours)
1 WEEK .... 7D 00H (7 days and 00 hours)
← key: Shifting the position of enter cursor
to the left for each character.
→ key: Shifting the position of enter cursor
to the right for each character.
DEL key: Deleting the character in the
position of enter cursor for each
character.
CLEAR key: Deleting all the entered characters.
• Youcanenterthevaluebypressingthenumber
buttons (0 to 9) while holding down the NUM
button on the remote control.
• Whenthevalueyouenteredmeetsthefollowing
conditions, an error dialog box is displayed at
the screen center.
∙ The value has been cleared by DEL or CLEAR
and left blank.
∙ The value you entered is out of the setting
range.
24H ......... 25H or over
1 WEEK ... 7D 01H or over
∙ The value of each item is out of the setting
range.
D .................. 8 or over (1 WEEK only)
H .................. 25 or over
10. When selecting OK, the setting is completed as
the lamp-switching interval stored. However, when
selecting CANCEL, the setting is completed without
storing.
• ThedisplayreturnstheLAMPRELAYmenuafter
selecting OK or CANCEL.
• ThesettingyoumadeisappliedtoNEXTLAMP
RELAY in the INFORMATION menu.
Important:
• Whenyouusetheprojectorcontinuously,thelamp
relay may not be performed on time due to errors of
the clock function.
• Immediatelyafterthepower-on,duringthelamp
selection, or during the lamp relay operation, you
cannot change the setting of LAMP SELECT and
LAMP RELAY.
• Inthecaseofcontinuousprojection,thelampsmay
deteriorate earlier unless they are turned off for 1
hour per week.
• Whenusingthisprojectorcontinuouslyforalong
time of period, enable LAMP RELAY.
• Thebrightnessandcolortintvaryatthetimeof
lamp switching.