Monarch 9860 Printer User Manual


 
Error Description/Action
002 Name must be 1 to 8 characters inside quotes.
005 Supply width is invalid.
018 Code page selection defined in the field must be 0
(Internal), 1 (ANSI), 100 (Macintosh), 101 (Wingdings),
102 (UNICODE), 103 (BIG5 for UNICODE), 104
(GB2312 for UNICODE), 105 (SJIS for UNICODE), 106
(GB2312), 107 (BIG5), 437 (DOS Page 437), 850 (DOS
Page 850), 852 (Latin 2), 855 (Russian), 857 (Turkish),
860 (Portuguese), 1250 (Latin 2), 1251 (Cyrillic), 1252
(Latin 1), 1253 (Greek), 1254 (Turkish), 1255 (Hebrew),
1256 (Arabic), 1257 (Baltic), or 1258 (Vietnamese).
025 Data length is too long.
101 Format referenced by batch not in memory.
400 Invalid character following {.
403 Field separator was not found.
409 Printer memory is full. Delete unnecessary formats or
graphics from memory.
410 Parity mismatch.
411 Framing error (baud rate mismatch).
412 Flow control mismatch.
413 Online receive buffer is full. Check for a flow control
problem.
611 Font, bar code, or density in the batch does not fit the
format.
612 The data in this line of the batch is either missing or
does not match the format.
12-8
Diagnostics & Troubleshooting