Software Installation
equal to zero) for one Moxa board.
Error msg:
No interrupt vector can be set for the Moxa ISA board (CAP=xxx).
Solution:
Moxa ISA boards need an interrupt vector. Refer to the "Hardware Installation" chapter
from the user's manual to set an interrupt vector.
Error msg:
Couldn't install the MOXA Smartio/Industio family driver!
Solution:
If loading the Moxa driver failed, the major number may conflict with other devices. Refer
to Section 3.7 to see how to edit the Moxa driver with a free major number.
Error msg:
Couldn't install MOXA Smartio family callout driver!
Solution:
If loading the Moxa callout driver failed, the callout device major number may conflict
with other devices. Refer to Section 3.7 to see how to edit the Moxa driver with a free
callout device major number.
Industio CP-134U Series User’s Manual
3-47