Moxa Technologies CP-134U Computer Hardware User Manual


 
Serial Programming Tools
How to transmit and receive data for Windows NT, and 95/98
In order to acquire precise timing control for RS-485 2-wire transmission, we recommend
that you configure your Industio CP-134U Series ports as described below.
There are 2 solutions to control RS-485 2-wire transmission.
Solution 1
The following method is commonly used for RS-485 2-wire transmission:
sio_SetWriteTimeouts(port, 0); /* Set sio_write() into block mode if for Windows
NT and Windows 95/98 */
sio_RTS(port, 1); /* Turn on RTS signal. The RS-485 port is ready for
transmitting data. */
sio_write(port, buff, 10); /* Write 10 byte characters in "buff". The function
blocks until the last character is transmitted */
sio_RTS(port, 0); /* Turn off RTS signal. The RS-485 port is ready for
receiving data. */
sio_read(port, buff, 10); /* Read 10 bytes */
Solution 2
PComm includes a dedicated RS-485 function that integrates the functions described in
solution 1 above into one function:
sio_putb_x(port, buff, tick ); /* 1. Turn on RTS and ready for transmitting data.
2. Send data.
3. Wait for tick time.
4. Turn off RTS and ready for receiving data. */
For more information on these functions, refer to the PComm library’s on-line Help file for
Windows NT and Windows 95/98.
Industio CP-134U Series User’s Manual
4-3