NEC 140He Server User Manual


 
8-4
STATUS lamp
indication
Description Action
Flashing green
The server is in operation with its
processor degraded.
Contact your service representative.
Start the BIOS SETUP and select [Main] - [Processor
Settings] to identify the degraded processor and replace it
as soon as possible.
Or, start the BIOS SETUP and select [Main] - [Processor
Settings] - [Processor Retest] - [Yes], and then select [Exit] -
[Exit Saving Changes] to solve the problem.
The server is in operation with its
memory degraded.
Contact your service representative.
Start the BIOS SETUP and select [Advanced] - [Memory
Configuration] to identify the degraded memory (DIMM) and
replace it as soon as possible.
Or, start the BIOS SETUP and select [Advanced] - [Memory
Configuration] - [Memory Retest] - [Yes], and then select
[Exit] - [Exit Saving Changes] to solve the problem.
A correctable memory or bus
error was detected.
The system can continue operation if the status lamp
flashes green. However, consult with your service
representative.
Unlit The server is powered off. Power on the server.
POST is in progress. Wait for a while. The STATUS lamp will light in a few
seconds after POST completion.
A processor error occurred
(IERR).
A processor thermal error was
detected. (Thermal-Trip)
Cycle power to the server. If POST displays an error
message, take a note on the message and contact your
service representative.
A watchdog timer has timed out.
A PCI system error occurred.
A PCI parity error occurred.
An uncorrectable memory error
was detected.
An uncorrectable bus error was
detected.
POST terminates with error.
Memory dumping is requested. Wait until memory dumping completes.
Lit amber A thermal error (critical) was
detected.
Check internal fans for dust or debris. Also make sure that
the fans are firmly connected.
If this error indication persists, contact your service
representative.
A voltage error (critical) was
detected.
Contact your service representative.
A power supply(ies) failed to
operate.
Contact your service representative.
Flashing
amber
A power alarm was detected in a
power supply unit.
Identify the failed power supply unit and contact your
service representative.
A fan alarm was detected. Make sure that the fan units are firmly connected.
If this error indication persists, contact your service
representative.
A thermal error (warning) was
detected.
Check internal fans for dust or debris. Also make sure that
the fan units are firmly connected.
If this error indication persists, contact your service
representative.
A voltage error (warning) was
detected.
Contact your service representative.