NEC 140He Server User Manual


 
8-25
Messages displayed on upper line
On-screen
message
Description Action
Prepare To Boot POST completes normally. This is not an error.
CPU Reconfigured
POST completes with processor
degraded.
Contact your service representative.
Try the following steps to cancel the error.
1. Start BIOS SETUP.
2. Select [Main] - Processor Settings] - [Processor
Retest] - [Yes].
3. Select [Exit] - [Exit Saving Changes].
Mem Reconfigured POST completes with memory degraded. Contact your service representative.
Try the following steps to cancel the error.
1. Start BIOS SETUP.
2. Select [Advanced] - [Memory Configuration] -
[Memory Retest] - [Yes].
3. Select [Exit] - [Exit Saving Changes].
M#1 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #1.
M#1 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #1.
M#1 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #1.
M#1 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #1.
M#2 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #2.
M#2 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #2.
M#2 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #2.
M#2 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #2.
The system can continue operation. However,
consult with your service representative.
On-screen
message
Description Action
M#3 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #3.
M#3 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #3.
M#3 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #3.
M#3 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #3.
M#4 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #4.
M#4 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #4.
M#4 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #4.
M#4 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #4.
The system can continue operation. However,
consult with your service representative.
M#1 D#1 UC Err
M#1 D#2 UC Err
An uncorrectable error occurs in DIMM #1
or DIMM #2 on memory board #1.
M#1 D#3 UC Err
M#1 D#4 UC Err
An uncorrectable error occurs in DIMM #3
or DIMM #4 on memory board #1.
M#2 D#1 UC Err
M#2 D#2 UC Err
An uncorrectable error occurs in DIMM #1
or DIMM #2 on memory board #2.
M#2 D#3 UC Err
M#3 D#4 UC Err
An uncorrectable error occurs in DIMM #3
or DIMM #4 on memory board #2.
M#3 D#1 UC Err
M#3 D#2 UC Err
An uncorrectable error occurs in DIMM #1
or DIMM #2 on memory board #3.
The system can continue operation if the status lamp
flashes green. However, consult with your service
representative.