NETGEAR GS728TP Network Router User Manual


 
29
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
When the management VLAN is set to a different value, an IP connection can be made
only through a port that is part of the management VLAN. It is also mandatory that the
port VLAN ID (PVID) of the port to be connected in that management VLAN be the same
as the management VLAN ID.
Note: Make sure that the PVID of at least one port that is a port of the
VLAN is the same as the management VLAN ID. For information
about creating VLANs and configuring the PVID for a port, see
VLANs .
The management VLAN has the following requirements:
Only one management VLAN can be active at a time.
When a new management VLAN is configured, connectivity through the existing
management VLAN is lost.
The management station must be reconnected to the port in the new management
VLAN.
5. Click APPLY to apply the changes to the system.
IPv6 Network Configuration
Use the IPv6 Network Configuration screen to configure the IPv6 network interface, which is
the logical interface used for in-band connectivity with the switch through all of the switch's
front-panel ports. The configuration parameters associated with the switch's network
interface do not affect the configuration of the front-panel ports through which traffic is
switched or routed.
To access the switch over a IPv6 network, you must initially configure the switch with IPv6
information (IPv6 prefix, prefix length, and default gateway). IPv6 can be configured using
IPv6 autoconfiguration.
When in-band connectivity is established, IPv6 information can be changed using any of the
following:
SNMP-based management
Web-based management