Chapter 5 Maintenance — Lamp/temperature/lter indicators
156 - ENGLISH
Temperature indicator <TEMP>
Indicator status Lighting in red
Flashing in red
(2 times)
Flashing in red
(3 times)
Status Warm-up status
Internal temperature is high
(warning).
Internal temperature is high
(standby status).
The cooling fan has
stopped.
Cause
f Did you turn on the power
when the temperature
was low (around 0 °C
(32 °F))?
f Is the air intake/exhaust port blocked?
f Is the room temperature high?
f Is the lter indicator <FILTER> lit?
―
Solution
f Wait at least ve minutes
in the current status.
f Install the projector in a
location with an ambient
temperature of 0 °C
(32 °F) to 45 °C (113 °F)
*1
.
f Remove any objects that are blocking the air intake/
exhaust port.
f Install the projector in a location with an ambient
temperature of 0 °C (32 °F) to 45 °C (113 °F)
*1
.
f Do not use the projector at high altitudes of 2 700 m
(8 858') or higher above sea level.
f Clean or replace the air lter unit. (x page 157)
f Turn the <MAIN POWER>
switch to <OFF>
(x page 55), and
consult your dealer.
*1 When using the projector at high altitudes (1 400 m (4 593') or higher – lower than 2 700 m (8 858') above sea level), the operating environment
temperature should be between 0 °C (32 °F) and 40 °C (104 °F).
If you use the Smoke cut lter, the operating environment temperature should be between 0 °C (32 °F) and 35 °C (95 °F). However, it cannot be
used at high altitudes.
If you use the Replacement lamp unit (for portrait mode), the operating environment temperature should be between 0 °C (32 °F) and 40 °C
(104 °F) when using the projector at elevations lower than 1 400 m (4 593') above sea level, and between 0 °C (32 °F) and 35 °C (95 °F) when
using the projector at high altitudes. If you use the Smoke cut lter together, the operating environment temperature should be between 0 °C (32 °F)
and 30 °C (86 °F).
Note
f If the temperature indicator <TEMP> is still lit or ashing after taking the preceding measures, ask your dealer for repair.
f If you use the projector with the following two settings made, the light output may drop by approx. 20 % to protect the projector when an
ambient temperature becomes 40 °C (104 °F) or higher (35 °C (95 °F) or higher if [HIGH ALTITUDE MODE] is set to [ON], or if the Smoke
cut lter is used).
g When [LAMP SELECT] is set to [DUAL] from the menu
g When [LAMP POWER] is set to [HIGH], [MIDDLE], or [NORMAL] from the menu
Filter indicator <FILTER>
Indicator status Lighting in red Flashing in red
Status
The lter is clogged.
The temperature inside or outside the projector is abnormally high.
The air lter unit is not
attached.
Cause f Is the air lter unit dirty?
f Is the air intake/exhaust
port blocked?
f Is [HIGH ALTITUDE
MODE] set correctly?
f Is the air lter unit
attached?
Solution
f Clean or replace the air
lter unit. (x page 157)
f Remove any objects that
are blocking the air intake/
exhaust port.
f When using the projector
at high altitudes between
1 400 m (4 593') or higher
and lower than 2 700 m
(8 858') above sea level,
set [HIGH ALTITUDE
MODE] (x page 109) to
[ON].
f Do not use the projector
at high altitudes of
2 700 m (8 858') or higher
above sea level.
f Attach the air lter unit.
Note
f If the lter indicator <FILTER> is still lit or ashing after taking the preceding measures, ask your dealer for repair.
f If the lter is clogged, only one lamp may light even when [LAMP SELECT] is set to [DUAL]. By cleaning the air lter unit or replacing it with
a new one, the lamp will light properly.