Planet Technology IDL-2400 Network Card User Manual


 
IDL series User Guide
606
- Crash in CP self processing
- DP Init Failure
- CP crashed after DP Init
- DP crashed after DP Init
- DP internal Failure
- System in Loop
- Crash in DP Processing
SystemUpTime
This specifies the system up time in:
Days : Hours : Minutes : Seconds
PSR Reg
This specifies the value of the processor state register at the
time of the crash.
Wim Reg
The window invalid mask register.
PC
This specifies the value of the program counter at the time of
the crash.
nPC
This specifies the value of the next program counter at the
time of the crash.
Y Reg MSW
This specifies the value of MSW of the Y Register at the time
of the crash.
Y Reg LSW
This specifies the value of LSW of the Y Register at the time of
the crash.
Trap Num
This specifies the number of traps that caused the crash.
Trap Base Reg
This specifies the value of the Trap Base register at the time of
the crash.
Fault Status Reg
This specifies the value of the Fault Status Register at the time
of the crash.
Double Fault Reg
This specifies the value of the Double Fault Register at the
time of the crash.
IER
This specifies the value of the Implementation Extension
Register at the time of the crash.
Alternate Window - Reg#
Local
For crashes involving Alternate Windows, this capture
specifies all local register for Alternate Windows # 24 to 31
(0x1f to 0x18).
Alternate Window - Reg#
In
For crashes involving Alternate Windows, this capture
specifies all input register for Alternate Windows # 24 to
31(0x1f to 0x18).
Standard Window Dump
- Registers - Global
The Sparclet Global register.
Standard Window Dump
- Registers - Out
The output registers of the specified Sparclet Window.
Standard Window Dump