RFID CONTROL Menu Items
27
Error Handling
This menu item selects the error handling mode for RFID failures.
The default is Overstrike.
In Overstrike mode, each failed label prints with the Overstrike
pattern and the form retries on a new label until the Label Retry
count is exhausted. Whether or not an error message will display or
the failed label will reprint depends upon the Max Retry Error
setting.
In None mode, no specific action is taken when a tag fails to be
programmed.
In Stop mode, when a tag fails to be programmed, the printer will
halt and display the error message “RFID Error: Check Media.” The
label is discarded and reprinting of the label (if desired) must be
initiated from the host. When the error is cleared, the label with the
failed tag moves forward until the next label is in position to be
printed.
Label Retry
NOTE: Label Retry only applies when the Error Handling mode is
set to Overstrike.
This menu item selects the number of label retries that the RFID
encoder will attempt before declaring a fault. This may indicate a
problem with the RFID encoder, the coupler assembly, the printer
setup, or the label stock. The default is 10.
Max Retry Error
This menu item enables or disables Max Retry Error. If it is set to
Disable, errors are not declared and the print content for the current
label is discarded. The default is Enable.
Tag Write Cnt
This menu item displays on the control panel’s LCD the number of
tags attempted to be written since the last Clear Tag Stat operation
has been initiated. (See “Clear Tag Stat” below.)