Printronix SL5000r MP Printer User Manual


 
Chapter 2 RFID CONTROL Menu
32
Custom Read Pwr
NOTE: To enable this menu item, set Custom Tag to Enable.
This menu item selects the read power level to be used in the RFID
encoder. 1 is the lowest power level setting, and 20 is the highest.
The default is 5.
Custom Tag Len
NOTE: To enable this menu item, set Custom Tag to Enable.
This menu item selects the number of bytes in the tag.
The default is 12.
Custom Tag Class
NOTE: To enable this menu item, set Custom Tag to Enable.
This menu item selects the class of the custom tag. Class 1,
Class 0+, Class 1.19, Class Gen 2, and Class Zuma tags are
read/write. Class 0 tags are read only. The default is Class 1.
Custom Rd Tries
NOTE: To enable this menu item, set Custom Tag to Enable.
This menu item selects how many times the RFID encoder will try
each read command. The default is infinite, which causes the
encoder to try until the operation times out.
Custom Wr Tries
NOTE: To enable this menu item, set Custom Tag to Enable.
This menu item selects how many times the RFID encoder will try
each write command. The default is 9.
Cust Early Write
NOTE: To enable this menu item, set Custom Tag to Enable.
This menu item selects how early the RFID encoder will write the
next tag before it completes the printing on the current label.