Write or Read RFID Format
57
and uses the value on the control panel’s
LCD.
motion
Set this flag to 1 to program data into the
tag without moving the label. The printer
may adjust the label position while it
writes data into the tag, but this
adjustment will reverse before any
subsequent normal label movement.
Even if this flag is set to 1, other
commands (i.e., alpha or barcode) may
move the label.
protect
This flag indicates whether the data
should be protected from being
overwritten later. The default is 0,
meaning the data are not protected.
Other acceptable values are 1 to 255,
meaning the data are protected using
this number as the LOCK password.
data format
0 (ASCII) or 1 (hex). The default is 0.
reserved
This is a reserved flag. The PPI/ZGL
absorbs this number.
Write or Read RFID Format
Purpose This command allows you to write or read to an RFID
tag.
Format ^RF
a
,
b
,
c
,
d
^RF Write or Read RFID command.
a
Specifies the read or write option. The
default is W.
W = write to the tag
L = write with LOCK
R = read the tag
b
Specifies the data format. The default is H.
A = ASCII
H = Hex
E = EPC format