Table 6. ZGL EPC Format Handling
EPC Format
(based on
header)
Selected
Tag Data
Length
Size of Data
Request (from
program)
Result Comment
64 bit 64 bit < 64 bit OK Pad 0s on right for 64 bit
64 bit 64 bit = 64 bit OK As is
64 bit 64 bit > 64 bit Error Data too long
64 bit 96 bit < 64 bit Read 96 bit Pad 0s on right for 64 bit
64 bit 96 bit = 64 bit Read 96 bit Pad 0s on right for 64 bit
64 bit 96 bit 64 bit <> 96 bit Read 96 bit Pad 0s on right for 64 bit
64 bit 96 bit = 96 bit Error EPC incompatible with
length
64 bit 96 bit > 96 bit Error Data too long
96 bit 64 bit < 64 bit Error EPC incompatible with
length
96 bit 64 bit = 64 bit Error EPC incompatible with
length
96 bit 64 bit > 64 bit Error Data too long
96 bit 96 bit < 96 bit OK Pad 0s on right for 64 bit
96 bit 96 bit = 96 bit OK As is
96 bit 96 bit > 96 bit Error Data too long