Printronix SL5000r MP Printer User Manual


 
Chapter 2 RFID PPI/ZGL Commands
58
c
Specifies the starting block number. The
default is 0. Since there are currently only
8–byte or 12–byte blocks, the starting
block number can only be 0.
d
Specifies the number of blocks to read.
This option is valid only for the read
operation. Since there are currently only
8–byte or 12–byte blocks, the number of
blocks to be read can only be 1.
Calibrate RFID Transponder Position
Purpose This command initiates an RFID RFID transponder
calibration for a specific RFID label and returns the
results to the host computer.
Format ^HR
a
,
b
^HR Calibrate RFID command.
a
The start string to appear before the
returned result. The default is “start”. The
acceptable value is any string less than 65
characters.
b
The end string to appear after the returned
result. The default is “end”. The acceptable
value is any string less than 65 characters.
Define EPC Data Structure
Purpose This command defines the structure of EPC data,
which can be read from or written to an RFID
transponder.
Format ^RB
p0
,
p1
,
p2
...,
p15
^RB EPC Data command.
n
Total bit size of the field. The default is 96.
The acceptable value range is 1 to
n
,
where
n
is the total bit size of the tag.
p1
...
p15
Specifies each partition size. These must
add up to the total bit size. The default is 1.