B – Command Line Interface
Show Command
B-64 59042-07 A
0
topology
Displays all connected devices.
users
Displays a list of logged-in users. This is equivalent to the User List command.
LogLevel Event severity level used to record
events in the event log
MaxPorts Number of ports available on the switch
NumberOfResets Number of times the switch has been
reset over its service life
ReasonForLastReset Action that caused the last reset
ActiveImageVersion - build date Active firmware image version and build
date.
PendingImageVersion - build date Firmware image version and build date
that is pending. This image will become
active at the next reset or power cycle.
ActiveConfiguration Name of the switch configuration that is
in use.
AdminState Switch administrative state
AdminModeActive Admin session status
BeaconOnStatus Beacon status as set by the Set Beacon
command.
OperationalState Switch operational state
PrincipalSwitchRole Principal switch status. True indicates
that this switch is the principal switch.
BoardTemp (1) - Degrees Celsius Internal switch temperature at circuit
board sensor 1
BoardTemp (2) - Degrees Celsius Internal switch temperature at circuit
board sensor 2
SwitchDiagnosticsStatus Results of the power-on self test
SwitchTemperatureStatus Switch temperature status: normal,
warning, failure
Table B-16. Switch Operational Parameters (Continued)
Parameter Description