Q-Logic 59042-07 A Switch User Manual


 
A – Specifications
Environmental
A-4 59042-07 A
0
A.6
Environmental
A.7
Regulatory Certifications
Temperature
Operating ..................................
Non-operating ...........................
5 to 50°C (41 to 122°F)
-40 to 65°C (-40 to 149°F)
Humidity
Operating ..................................
Non-operating ...........................
15% to 80%, non-condensing
25% to 90%, non-condensing
Altitude
Operating ..................................
Non-operating ...........................
0 to 3048m (0 to 10,000 feet)
0 to 15,240m (0 to 50,000 feet)
Vibration
Operating ..................................
Non-operating ...........................
IEC 68-2
5-500 Hz, random, 0.21 G rms, 10 minutes
5-500 Hz, random, 2.09 G rms, 10 minutes
Shock
Operating ..................................
Non-operating ...........................
IEC 68-2
4 g, 11ms, 20 repetitions
30g, 292 ips, 3 repetitions, 3 axis
Air flow............................................ Front-to-back or back-to-front, by model
Safety Standards ............................ UL1950, CSA 22.2 No. 950, EN60950
Emissions Standards ...................... FCC Part 15B Class A
ICES-03 Issue 3
VCCI Class A ITE
BSMI Class A
CISPR 22, Class A
EN 55022, Class A
Voltage Fluctuations ....................... EN 61000-3-3
Harmonics....................................... EN 61000-3-2
Immunity ......................................... EN 55024:1998
Marking........................................... FCC Part 15,UL (United States), cUL
(Canada), TUV, VCCI, BSMI, CE
SANmark® SCD 3001, 3002, 3010, 3020