Q-Logic SB2A-16B Switch User Manual


 
B – Command Line Interface
Set Command
B-30 59021-08 B
D
Set Command
Sets a variety of switch parameters.
Authority Admin session for all keywords except Beacon and Pagebreak which are
available without an Admin session.
Syntax set
alarm clear
beacon [state]
config [option]
log [option]
pagebreak [state]
port [option]
setup [option]
switch [state]
Keywords alarm clear
Clears the alarm log.
beacon [state]
Enables or disables the flashing of the Logged-In LEDs according to [state]. This
keyword does not require an admin session. [state] can be one of the following:
on
Enables the flashing beacon.
off
Disables the flashing beacon.
config [option]
Sets switch, port, port threshold alarm, and zoning configuration parameters.
Refer to the ”Set Config Command” on page B-32.
log [option]
Specifies the type of entries to be entered in the event log. Refer to the ”Set Log
Command” on page B-43.
pagebreak [state]
Specifies how much information is displayed on the screen at a time according to
the value given by [state]. This keyword does not require an admin session. [state]
can be one of the following:
on
Limits the display of information to 20 lines at a time. The page break
functions affects the following commands: Alias (List, Members), Show
(Alarm, Log), Zone (List, Members), Zoneset (List, Zones), Zoning (Active,
List).
off
Allows continuous display of information without a break.