Q-Logic SB2A-16B Switch User Manual


 
B – Command Line Interface
Set Config Command
59021-08 B B-35
D
InbandEnabled Inband management. Enables (True) or
disables (False) the ability to manage
the switch over an ISL. The default is
True.
FDMIEnabled Fabric Device Monitoring Interface.
Enables (True) or disables (False) the
monitoring of target and initiator device
information.
FDMIEntries The number of device entries to
maintain in the FDMI database. Enter a
number from 0–1000. The default is
1000.
DefaultDomainID Default domain ID. The default is 1.
DomainIDLock Prevents (True) or allows (False)
dynamic reassignment of the
domain ID. The default is False.
SymbolicName Descriptive name for the switch. The
name can be up to 32 characters
excluding #, semicolon (;), and comma
(,). The default is SANbox2.
R_A_TOV Resource Allocation Timeout Value.
The number of milliseconds the switch
waits to allow two ports to allocate
enough resources to establish a link.
The default is 10000.
E_D_TOV Error Detect Timeout Value. The
number of milliseconds a port is to wait
for errors to clear. The default is 2000.
PrincipalPriority The priority used in the FC-SW-2
principal switch selection algorithm. 1 is
high, 255 is low. The default is 254.
ConfigDescription Switch configuration description. The
configuration description can be up to
32 characters excluding #, semicolon
(;), and comma (,). The default is
SANbox2-16 FC Switch.
Table B-10. Set Config Switch Parameters (Continued)
Parameter Description