Q-Logic SB2A-16B Switch User Manual


 
4 – Installation
Installing a Switch
4-10 59021-08 B
D
d. Enter the following COM Port settings in the COM Properties
window and choose the OK button.
Bits per second: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
For Linux:
a. Set up minicom to use the serial port. Create or modify the
/etc/minirc.dfl file with the following content:
pr portdev/ttyS0
pu minit
pu mreset
pu mhangup
pr portdev/ttyS0 specifies port 0 on the workstation.
Choose "pr" setting to match the workstation port to which you
connected the switch.
b. Verify that all users have permission to run minicom. Review the
/etc/minicom.users file and confirm that the line "ALL" exists or
that there are specific user entries.
c. Enter the following command at the Linux prompt:
minicom
For Solaris:
a. Set up Solaris to use the serial port. Modify the /etc/remote file to
include the following lines. /dev/term/a refers to serial port a.
Choose the "dv" setting to match the workstation port to which
you connected to the switch.
SANbox2:
\:dv=/dev/term/a:br#9600:el=^C^S^Q^U^D:ie=%$:oe=^D:
b. Enter the following command at the Solaris prompt:
# tip sanbox2
3. Log in to the switch. If fabric security is disabled, account names and
passwords are not enforced. Refer to the ”Set Setup Command” on
page B-48 for information about setting fabric security. The default account
name and password are (admin, password).
SANbox2 Login: admin
Password: ********