Seagate DL585 Server User Manual


 
Removal and replacement procedures 25
Figure 16 Four DIMM slots
Table 5 Processor memory board memory banks with four DIMM slots
Slot Bank
5–6 Bank 1
7–8 Bank 2
Removing a DIMM
1. Power down the server. See “Powering down the server” earlier in this chapter.
2. Extend the server from the rack. See “Extending the server from the rack” earlier in this chapter.
3. Remove the access panel. See “Removing the access panel” earlier in this chapter.
4. Remove the processor memory board. See “Processor memory boards” earlier in this chapter.
5. Remove the DIMM.
Figure 17 Removing a DIMM
IMPORTANT: Be sure all DIMM retention clips are in the closed/locked position before reinstalling processor
memory board into the system.
Reverse the removal steps to install a DIMM.