Sharp AR-160 Copier User Manual


 
Main
code
Sub
code
Contents Details of operation
Initial
value
Set range
7 2 Aging without JAM with
warmup time display
Used to start warmup and count and display the warmup time every
second. After completion of warmup, count up is terminated and the
ready lamp is lighted. When the clear key is pressed and the copy
quantity is entered and the start key is pressed, copying is made to make
the set quantity of copies. At that time, the paper size does not matter.
1 ~ 99
Key operation
Copy quantity setting: Numeric keys
4 Warmup saving Used to bring the machine to the ready state without warmup.
6 Intermittent aging (with
paper)
After completion of warmup, counting is stopped and the ready lamp is
lighted. When the copy quantity is entered and the start key is pressed,
copying is made to make the set quantity of copies. After 3 sec standby,
copying is made again to make the set quantity of copies. After that this
operation is repeated. The paper size does not matter.
1 ~ 99
Key operation
Copy quantity setting: Numeric keys
7 Intermittent aging (without
paper)
After completion of warmup, counting is stopped and the ready lamp is
lighted. When the copy quantity is entered and the start key is pressed,
copying is made to make the set quantity of copies. After 3 sec standby,
copying is made again to make the set quantity of copies. After that this
operation is repeated. The paper size does not matter.
1 ~ 99
Key operation
Copy quantity setting: Numeric keys
8 Warmup time display Used to count and display the warmup time from 0 at every second.
8 1 Developing bias voltage
output check
Used to output the developing bias for 30 sec. For the adjustment proce-
dure of the developing bias, refer to the previous descriptions.
2 Main charger voltage
output check (Grid bias
high mode)
Used to output the main charger grid bias voltage at the high mode for
30 sec. For the adjustment procedure of the main charger grid bias
voltage, refer to the previous descriptions.
3 Main charger voltage
output check (Grid bias
low mode)
Used to output the main charger grid bias voltage at the low mode for 30
sec. For the adjustment procedure of the main charger grid bias voltage,
refer to the previous descriptions.
6 Transfer charger voltage
check
Used to output the transfer charger voltage for 30 sec. For the adjust-
ment procedure of the transfer charger voltage, refer to the previous
descriptions.
9 1 Duplex motor forward
rotation operation check
Used to rotate the duplex motor forward for 30 sec.
2 Duplex motor reverse
rotation operation check
Used to rotate the duplex motor reversely for 30 sec.
4 Duplex motor rotation
speed adjustment
After completion of warmup, the ready lamp is lighted and the currently
set duplex motor rotation speed set value is displayed.
When the set value is entered and the start key is pressed, the set value
is stored.
Key operation
Duplex motor rotation speed set value: Numeric keys
5 Duplex motor switchback
time adjustment
After completion of warmup, the ready lamp is lighted and the currently
set duplex motor switchback time set value is displayed.
When the set value is entered and the start key is pressed, the set value
is stored.
Key operation
Duplex motor switchback time set value: Numeric keys
10 Toner motor operation
check
Used to operate the toner motor for 30 sec.
Note: If this simulation is executed with the toner hopper installed, toner
is automatically supplied to the developer. Be careful of overtoner.
14 Trouble (except for U2)
cancel
Used to cancel troubles except for U2.
16 U2 trouble cancel Used to cancel U2 trouble.
17 PF trouble cancel Used to cancel PF trouble.
AR-160/160 FM/E [8] SIMULATION 12/1/1998
AR-161
8 – 4