Sony BVM-20F1U, BVM-20F1E, BVM-20E1U, BVM-20E1E, BVM-14F1U, BVM-14F1E, BVM-14E1U, BVM-14E1E, BVM-14F5U, BVM-14F5E, BVM-14E5U, BVM-14E5E Computer Monitor User Manual


 
30
Chapter 2 Menus
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
To access the MANUAL menu directly
When the [F2] button is assigned as the short-cut
key to the MANUAL menu, you can directly
access the MANUAL menu that corresponds to the
color temperature setting set to the image on the
screen.
For details of how to assign the short-cut key, see
“Setting the Power-Up Conditions - SYSTEM
CONFIGURATION Menu” on page 42.
[B12] PROBE menu
Select the probe for color temperature adjustment.
SONY BKM-14L...: Use the BKM-14L. ÷ [B121]
GRASEBY SLS 9400...: Use the SLS 9400. ÷
[B122]
MINOLTA CA-100...: Use the CA-100. ÷ [B122]
PHILIPS PM 5639...: Use the PM 5639. ÷ [B122]
THOMA TF6...: Use the TF6. ÷ [B122]
If you cannot execute an ADJUST or ANALYZE
menu operation when using the Sony BKM-14L
probe, try again after disconnecting and
reconnecting the probe.
•When using the Thoma TF6 probe, set the TF6
PRINT menu to off.
[B121] SONY BKM-14L menu
Select the BKM-14L operation.
ADJUST...: Perform automatic color temperature
adjustment. ÷ [B1211]
ANALYZE: Display readout values on the screen.
÷ [B1212]
[B1211]
ADJUST menu
To start adjustment, proceed as follows.
When you use the previously adjusted values for
adjustment, you can make start adjustment by selecting
START without perform operations step (1) and step
(2).
(1) Select either D65 or D93.
Rather than selecting D65 or D93, you may instead
enter the values of the CIE 1931 color system x
and y coordinates.
(2) Enter values for LOWLIGHT and HIGHLIGHT.
(3) Select START.
START: Start adjustment. ÷ [B12111]
X: Enter the x coordinate.
Y: Enter the y coordinate.
LOW LIGHT (20IRE): Enter the brightness (cd/m
2
)
for low light.
HIGH LIGHT (100IRE): Enter the brightness (cd/
m
2
) for high light.
D65: Use D65 setting.
D93: Use D93 setting.
[B12111]
START menu
The following message appears. Perform operation
according to the message to start adjustment.
SET PROBE ON CRT
PRESS ENTER
Adjustment starts when the probe is placed against the
center of the screen and the ENTER button is pressed.
[B1212] ANALYZE menu
The following message appears. Perform operation
according to the message to enable the BKM-14L to
read the color system and luminance value.
SET PROBE ON THIS CRT
PRESS ENTER
Attach the BKM-14L to the center of the monitor
screen and press Enter. ÷ [B12121]
Once the calibration has been carried out, you can use
the probe to analyze the monitor’s performance.
[B12121] ANALYZE menu
Display color temperature and luminance readout
values from the BKM-14L at the bottom of the screen.
X: xxxx: Display the color temperature x coordinate
value.
Y: xxxx: Display the color temperature y coordinate
value.
L: xxxx: Display the luminance value.
[B122]
GRASEBY/MINOLTA/PHILIPS/THOMA
menu
The contents and function of this menu are the same as
those of the ADJUST menu [B1211] .
[B13]
COPY menu
Select the source to be copied from.
OTHER VALUE...: Copy data from another channel
or from common data. ÷ [B131]
OTHER MONITOR...: Copy data from another
monitor. ÷ [B132]
MEMORY CARD...: Copy data from a memory
card. ÷ [B133]