1-9
MVS-8000SF
1-5. Rack Mounting
1-5. Rack Mounting
The MVS-8000SF is mounted in the 19-inch standard rack.
To mount the MVS-8000SF in the rack, use the specified
rack mount kit and follow the procedure described below.
Specified rack mount kit : RMM-10
n
If other than the specified rack mount kit is used, the unit
may not be mounted in the 19-inch standard rack.
Parts of the RMM-10
. Rack tool 2 pcs
. Right rack mount adapter 1 pc
. Left rack mount adapter 1 pc
. Rack tool attaching screw 6 pcs
(B4 x 6 : 7-682-560-09)
. Rack tool attaching screw 6 pcs
(B4 x 10 : 7-682-560-10)
Other required parts
To mount in the rack, the rack mount kit RMM-10 and the
following part are required.
. Screw for rack mounting 4 pcs
(B5 x 12 : 7-682-576-04)
1. Precautions for Rack Mounting
w
. To prevent the rack from falling or moving, fix the rack
on a flat and steady floor using bolt or others.
If the rack falls due to the weight of the equipment, it
may cause death or injury.
. Be sure to use the specified rack mount kit.
If not, injury may result and the equipment may fall due
to insufficient strength.
. After rack mounting, be sure to tighten the screws on the
rack angle and fix the unit in the rack.
If the screws on the rack angle are not tightened, the unit
may slip from the rack and fall, causing injury.
c
When mounting the unit in the rack, note the following:
. Be sure to mount in the rack with two persons or more.
. Be careful not to catch your fingers or hands in the rack
mount rail or others.
. Mount in the rack in a stable position.
n
If several units are mounted in a rack, it is recommended to
install a ventilation fan to prevent temperature rise inside
the rack.
2. Rack Mounting Procedure
This section describes the rack mounting procedure using
the RMM-10 rack mount kit.
n
Tighten the screws to the following torque.
Tightening torque : 120 x 10
_2
N.m {12.2 kgf.cm}
1. Attach the rack tool to the side of the equipment using
the specified six screws.
n
Use B4 x 6 screws.
B4 x 6
B4 x 6
Rack tool
Rack tool