Sony MVS8000SF-C Laptop User Manual


 
1-45
MVS-8000SF
<Connector>
CN1600 (A-5) : ISP common connector
Used only for production in the assembly factory. Used for
program writing into the JTAG device with ISP.
CN1902 (A-7) : TERMINAL pin
This pin is connected to the control terminal and used
during maintenance.
<TEST terminal>
E1 (A-5), E2 (N-1), E3 (N-5), E4 (N-12), E5 (J-1), E6 (G-7),
E7 (G-12) : GND terminal
Use this terminal as the earth point for measuring the
respective check terminals.
TP1 (A-3) :
++
++
+12 V check terminal
+12 V measuring terminal.
TP201 (M-12) : VD (vertical sync) signal check terminal
VD signal measuring terminal.
TP202 (M-12) : CKX (control timing) signal check terminal
CKX signal measuring terminal.
TP203 (M-12) : HD (horizontal sync) signal check
terminal
HD signal measuring terminal.
TP204 (M-12) : FLOE (field odd even) signal check
terminal
FLOE signal measuring terminal.
TP205 (J-12), TP206 (J-7) : CK (clock for video)
signal check terminal
Uses this terminal when checking the clock signal for video.
TP700 (N-3) : CPU_CS2 signal check terminal
CPU_CS2 signal measuring terminal.
TP701 (M-5) : CPU_OE signal check terminal
CPU_OE signal measuring terminal.
TP702 (M-5) : CPU_WE signal check terminal
CPU_WE signal measuring terminal.
TP800 (L-11), TP900 (K-11), TP1000 (H-11), TP1100 (G-11),
TP1200 (L-5), TP1300 (K-5), TP1400 (H-5), TP1500 (G-5) :
ERR check terminal
SDI signal error measuring terminal.
TP2100 (B-8) : CPU CK (CPU clock) signal check
terminal
Uses this terminal when checking the CPU clock.
TP9001 (A-4) :
++
++
+1.8 V check terminal
+1.8 V measuring terminal.
TP9501 (A-4) :
++
++
+3.3 V check terminal
+3.3 V measuring terminal.
<LED on the CPU DK module> (C10)
Refer to < LED on the CPU DR module > in 1. CA-44
Board.
<Switch on the CPU DK module> (C10)
Refer to < Switch on the CPU DR module > in 1. CA-44
Board.
1-8. Checks on Completion of Installation