1-21
MVS-8000SF
1-8. Checks on Completion of Installation
..
..
. DO-44 board
<LED>
D1 (A-3) :
++
++
+12 V
+12 V power supply status indication.
Lit when the +12 V power is supplied.
If this LED does not light, the fuse may have blown.
D5 (A-4) : CONF ERR status LED
FPGA (EP20K100E) CONFIG DONE status indication.
Not lit when all configurations are completed.
D9004 (A-4) :
++
++
+1.8 V
+1.8 V power supply status indication.
Lit when the +1.8 V power is supplied.
D9504 (A-3) :
++
++
+3.3 V
+3.3 V power supply status indication.
Lit when the +3.3 V power is supplied.
DO-44 board A side/Component side
AB C DE F GH J K L MN P R
D1
D9504
D9004
TP9001
D5
E8
CN1
S2
S1
E2
E3
E7
E6
TP4
E1
E4 E5
TP5
TP8
TP9
TP9501
TP1
1
2
3
4
5
6
7
8
9
10
11
12
13
<Switch>
S1 (A-9) : Reset switch
Pressing this switch initializes the DO-44 board.
S2 (A-8) : JTAG switch
Used only for production in the assembly factory. Set this
switch to ON only when writing program in the JTAG
device with ISP.
<Connector>
CN1 (A-8) : ISP common connector
Used only for production in the assembly factory. Used for
program writing into the JTAG device with ISP.
<TEST terminal>
E1 (G-6), E2 (G-4), E3 (L-6), E4 (D-8), E5 (J-8), E-6 (M-12),
E-7 (N-9), E-8 (A-5) : GND terminal
Use this terminal as the earth point for measuring the
respective check terminals.