6000-100AppD.fm Rev. D TimeVault™ User’s Manual D-121
Symmetricom SNMP Enterprise MIB Appendix D: SNMP – Simple Network Management Protocol
actsBaudRate OBJECT-TYPE
SYNTAX INTEGER
{
baud300 (300),
baud1200 (1200),
baud9600 (9600),
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Indicates the baud rate setting for the ACTS modem. The ACTS
dial-up service accepts 300 or 1200 baud. Note: this is a rare case
where faster is not better and 300 baud yields the best time accuracy.”
::= { acts 2 }
actsFailRedial OBJECT-TYPE
SYNTAX INTEGER (0..9999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“When the dial-up session fails to connect this is the time in
seconds to wait to try again.”
::= { acts 3 }
actsMaxCallPeriod OBJECT-TYPE
SYNTAX INTEGER (0..999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“This is the maximum time in minutes the ACTS unit will wait between
successful calls to the ACTS service.”
::= { acts 4 }
actsPhoneNum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“This is the phone number of the ACTS dial-up service, including
any prefixes needed to reach an outside line or international dialing.
Prefixes are separated by a comma from the main phone number.”
::= { acts 5 }
actsNumberOfCalls OBJECT-TYPE
SYNTAX Counter
MAX-ACCESS read-only
STATUS current
DESCRIPTION
“Number of times the time server has called the ACTS dial-up
service - weather the call was successful or not.”
::= { acts 6 }