Feed Gap Sensor Sensitivity Adjustment
(for Label with Gaps)
1
Open the Top Cover.
2
Lift the Pinch Roller Lever to the ROLLER RELEASE position
to open the Pinch Roller Unit.
3
Insert the label with gaps into the Media Inlet so that the Feed
Gap Sensor can detect the LABEL part.
4
Lock the Pinch Roller Unit.
5
Turn on the printer.
6
Turn the Feed Gap Sensor Adjusting Knob to the left most position.
7
Keep turning the knob clockwise slowly. When the upper two
Feed Gap Sensor Lamps illuminate green, the adjustment is
complete.
Feed Gap Sensor Sensitivity Adjustment
(for Media with Rectangular Holes)
1
Open the Top Cover.
2
Lift the Pinch Roller Lever to the ROLLER RELEASE position
to open the Pinch Roller Unit.
3
Insert the media with rectangular holes into the Media Inlet so
that the Feed Gap Sensor can detect the PAPER part.
4
Lock the Pinch Roller Unit.
5
Turn on the printer.
6
Turn the Feed Gap Sensor Adjusting Knob to the left most position.
7
Keep turning the knob clockwise slowly. When the upper two
Feed Gap Sensor Lamps illuminate green, the adjustment is
complete.
Note:
As soon as the upper two lamps
illuminate green, stop turning the knob.
Note:
As soon as the upper two lamps
illuminate green, stop turning the knob.